São Paulo med. j ; 142(4): e2023177, 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1536907

ABSTRACT

ABSTRACT BACKGROUND: Contamination of the breathing circuit and medication preparation surface of an anesthesia machine can increase the risk of cross-infection. OBJECTIVE: To evaluate the contamination of the anesthetic medication preparation surface, respiratory circuits, and devices used in general anesthesia with assisted mechanical ventilation. DESIGN AND SETTING: Cross-sectional, quantitative study conducted at the surgical center of a philanthropic hospital, of medium complexity located in the municipality of Três Lagoas, in the eastern region of the State of Mato Grosso do Sul. METHODS: Eighty-two microbiological samples were collected from the breathing circuits. After repeating the samples in different culture media, 328 analyses were performed. RESULTS: A higher occurrence of E. coli, Enterobacter spp., Pseudomonas spp., Staphylococcus aureus, and Streptococcus pneumoniae (P < 0.001) were observed. Variations were observed depending on the culture medium and sample collection site. CONCLUSION: The study findings underscore the inadequate disinfection of the inspiratory and expiratory branches, highlighting the importance of stringent cleaning and disinfection of high-touch surfaces.

2.
Infectio ; 26(1): 67-72, ene.-mar. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1350850

ABSTRACT

Resumen Objetivo: describir el perfil microbiológico de las superficies inanimadas en contacto con el paciente en un hospital nivel III de la seguridad social de Chiclayo, Perú. Material y métodos: Se realizó un estudio transversal, con los datos de los informes del Control microbiológico cualitativo de ambientes físicos de 5 servicios de un Hospital de Chiclayo nivel III del Perú. El método para la identificación de microorganismos fue el sistema automatizado VITEK MS. Se presentan análisis des criptivos como frecuencias y porcentajes. Resultados: Se reportaron un total de 177 aislamientos, de los cuales 97,74% (173) fueron positivos, de estos, el 50,87% (88) estuvo conformado por bacilos gram negativos, siendo el microorganismo más aislado Acinetobacter baumannii (17 muestras) seguido de Rhizobium radiobacter (16) y Sphingomonas paucimobilis 13. Conclusiones: El ambiente hospitalario se encuentra altamente contaminado, siendo la mayoría microorganismos patógenos. Estos resultados guardarían relación con el prolongado tiempo de vida de los microorganismos en las superficies inertes y el proceso de limpieza y desinfección del ambiente hospitalario, por lo que la evaluación de su eficacia y el posible desarrollo de nuevas y mejores técnicas de limpieza deben ser motivo de investigación.


Abstract Objective: to describe the microbiological profile of inanimate surfaces in contact with the patient in a social security level III hospital in Chiclayo, Peru. Material and methods: An observational, descriptive, transversal study was carried out with the data from the reports of the Microbiological Qualitative Control of Physical Environments of 5 services of a Chiclayo Hospital level III in Peru. The method for the identification of microorganisms was the automated system VITEK MS. Descriptive analyses such as frequencies and percentages are presented. Results: A total of 177 isolations were reported, from which 97.74% (173) were positive, of these, 50.87% (88) were composed by gram-negative bacilli, being the most isolated microorganism Acinetobacter baumannii (17 samples) followed by Rhizobium radiobacter (16) and Sphingomonas paucimobilis 13. Conclusions: The hospital environment is highly contaminated, being most of them pathogenic microorganisms. These results would be related to the long life of microorganisms on inert surfaces and the process of cleaning and disinfection of the hospital environment, so the evaluation of its effectiveness and the possible development of new and better cleaning techniques should be investigated.

3.
Rev. eletrônica enferm ; 24: 1-11, 18 jan. 2022.
Article in English, Portuguese | LILACS, BDENF | ID: biblio-1411227

ABSTRACT

Objetivo: avaliar a presença de biofilme nas películas de smartphones de profissionais da saúde, investigar o padrão de uso e de descontaminação dos smartphones no ambiente de assistência à saúde em um hospital de médio porte. Métodos: estudo analítico e transversal, realizado com profissionais de saúde que possuíam smartphone. Foram realizadas entrevistas estruturadas e a presença de biofilme nas películas de vidro dos smartphones foi avaliada pela microscopia eletrônica de varredura. Resultados: todas as amostras de películas foram positivas para presença de biofilme, mesmo após descontaminação com álcool a 70%. Dos participantes, 96,4% utilizavam smartphone no ambiente de trabalho, a maioria utilizava o aparelho para fins pessoais e descontaminavam com álcool a 70% com frequência irregular. Conclusões: o smartphone pode servir como fômite, visto que biofilmes foram detectados na superfície das películas. Esses achados apontam para a necessidade de políticas de controle de infecção relacionadas ao uso dos smartphones.


Objective: to evaluate the presence of biofilm on the protective glass films of smartphones of health professionals, to investigate the pattern of use and decontamination of smartphones in the health care environment of a medium-sized hospital. Methods: analytical and cross-sectional study, carried out with health professionals with smartphones. Structured interviews were carried out and the presence of biofilm on the protective glass films of smartphones was evaluated by scanning electron microscopy. Results: all film samples were positive for the presence of biofilm, even after decontamination with alcohol 70%. 96.4% of the participants used a smartphone in the work environment, most used the device for personal purposes and decontaminated it with alcohol 70% with irregular frequency. Conclusion(s): the smartphones can serve as a fomite, considering that biofilms were detected on the surface of the films. These findings point to the need for infection control policies related to the use of smartphones.


Subject(s)
Equipment Contamination/prevention & control , Infection Control , Health Personnel
4.
Rev. bras. enferm ; 75(3): e20210216, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1357028

ABSTRACT

ABSTRACT Objectives: to identify the safe storage time for the use of flexible gastrointestinal endoscopes after high-level disinfection, as well as the defining criteria for this time. Methods: an integrative literature review was carried out in the Virtual Health Library, PubMed, Scopus, and Web of Science, considering original articles published since 2000. Results: eleven articles were selected, whose storage times ranged from 1 to 56 days, with a predominance of one to seven days (73%). Several criteria were used to define this time, predominantly the premise of efficient processing (100%), use of alcohol flush (64%), use of drying cabinets (18%), among others. Conclusions: the criteria for determining the storage time did not show a consensus for clinical practice. Expanding the discussion of this theme with the definition of the minimum necessary conditions is of fundamental importance for the reduction of risks and safety of the procedure and the patient.


RESUMEN Objetivos: identificar el tiempo de almacenamiento seguro para utilización de endoscopios flexibles gastrointestinales después de la desinfección de alto nivel, así como los criterios definidores de ese tiempo. Métodos: realizado una revisión integrativa de la literatura en la Biblioteca Virtual en Salud, PubMed, Scopus y Web of Science, considerando artículos originales publicados desde 2000. Resultados: fueron seleccionados 11 artículos, cuyos tiempos de almacenamiento variaron entre 1 y 56 días, con predominio de uno a siete días (73%). Utilizados diversos criterios para definición de ese tiempo, siendo predominantes la premisa del procesamiento eficiente (100%), uso de flush de alcohol (64%), armarios de secado (18%), entre otros. Conclusiones: los criterios para determinación del tiempo de almacenamiento no evidenciaron un consenso para práctica clínica. Ampliar la discusión de esa temática con definición de las condiciones mínimas necesarias es de fundamental importancia para la reducción de riesgos y seguridad del procedimiento y del paciente.


RESUMO Objetivos: identificar o tempo de armazenamento seguro para utilização de endoscópios flexíveis gastrointestinais após a desinfecção de alto nível, bem como os critérios definidores desse tempo. Métodos: realizou-se uma revisão integrativa da literatura na Biblioteca Virtual em Saúde, PubMed, Scopus e Web of Science, considerando artigos originais publicados desde 2000. Resultados: foram selecionados 11 artigos, cujos tempos de armazenamento variaram entre 1 e 56 dias, com predomínio de um a sete dias (73%). Utilizaram-se diversos critérios para definição desse tempo, sendo predominantes a premissa do processamento eficiente (100%), uso de flush de álcool (64%), uso de armários de secagem (18%), entre outros. Conclusões: os critérios para determinação do tempo de armazenamento não evidenciaram um consenso para prática clínica. Ampliar a discussão dessa temática com definição das condições mínimas necessárias é de fundamental importância para a redução de riscos e segurança do procedimento e do paciente.

5.
Rev. epidemiol. controle infecç ; 11(2): [1-16], abr.-jun. 2021. ilus
Article in English | LILACS | ID: biblio-1362644

ABSTRACT

Justificativa e Objetivos: As Infecções Relacionadas a Assistência à Saúde (IRAS) são um importante problema de saúde pública que causa impactos negativos nos custos hospitalares e prognóstico dos pacientes. Diante da importância do ambiente hospitalar no desenvolvimento das IRAS, objetiva-se avaliar o perfil bacteriano em superfícies e equipamentos da Clínica Ortopédica do Hospital Universitário do Vale do São Francisco. Métodos: Trata-se de um estudo transversal e descritivo de natureza quantitativa. As amostras foram coletadas em 13 enfermarias, onde foram amostrados superfícies e equipamentos dos leitos e das enfermarias, utilizando-se swabs embebidos em solução salina e um molde de papel filtro de área de 1cm2 a fim de padronizar as amostras. Após a passagem do swab, os mesmos foram armazenados em tubo contendo 5mL de meio líquido BHI (Brain Heart Infusion). Em seguida, as amostras foram transportadas para o Laboratório de Análises Clínicas/Setor Microbiologia, onde foram realizadas as análises microbiológicas. Resultados: Observou-se um total de 257 bactérias, sendo 5,11% possíveis causadoras de infecção hospitalar e 79% Staphylococcus coagulase negativa, as quais foram submetidas aos antibiogramas e mostraram diferentes perfis de resistência. A maçaneta do banheiro, uma superfície de alto toque, apresentou a maior variedade de espécies entre as superfícies avaliadas. Conclusão: Superfícies e equipamentos da clínica avaliada apresentam bactérias possíveis causadoras de infecção hospitalar com diferentes perfis de resistência antimicrobiana, contribuindo para possíveis infecções cruzadas.(AU)


Justificación y Objetivos: Las infecciones asociadas a la asistencia sanitaria (IAAS) son un importante problema de salud pública que impacta negativamente en los costos hospitalarios y el pronóstico de los pacientes. Dada la importancia del entorno hospitalario en el desarrollo de las IAAS, el objetivo fue evaluar el perfil bacteriano en superficies y equipos de la Clínica Ortopédica del Hospital Universitário do Vale do São Francisco. Métodos: Se trata de un estudio transversal, descriptivo y cuantitativo. Las muestras se recolectaron en 13 salas, cada sala con cuatro camas y una se eligió al azar, donde se muestrearon las superficies y el equipo utilizando hisopos empapados en solución salina y un molde de papel de filtro de 1cm2 para estandarizar las muestras. Después de pasar el hisopo, se almacenaron en un tubo que contenía 5 ml de medio líquido BHI (infusión cerebro corazón). Luego, las muestras fueron transportadas al Laboratorio de Análisis Clínicos/Sector de Microbiología, donde se realizaron los análisis microbiológicos. Resultados: Se observó un total de 257 bacterias, de las cuales el 5,11% fueron posibles causas de infección hospitalaria y el 79% Staphylococcus coagulasa negativo. Se realizaron antibiogramas de estos y se encontraron diferentes perfiles de resistencia. La manija del baño, una superficie de alto tacto, presentó la mayor variedad de especies entre las superficies evaluadas. Conclusiones: Las superficies y el equipo de la clínica evaluada presentan posibles bacterias que causan infección hospitalaria con diferentes perfiles de resistencia a los antimicrobianos, lo que contribuye a posibles infecciones cruzadas.(AU)


Background and Objectives: Healthcare-Associated Infections (HAIs) are an important public health problem that impacts negatively on hospital costs and patient prognosis. Given the importance of the hospital environment in the development of HAIs, the objective was to evaluate the bacterial profile on surfaces and equipment of the Orthopedic Clinic of the Hospital Universitário do Vale do São Francisco. Methods: This is a cross-sectional, descriptive, quantitative study. Samples were collected in 13 wards, each ward with four beds and one was chosen at random, where surfaces and equipment were sampled using swabs soaked in saline and a 1cm2 filter paper mold to standardize the samples. After passing the swab, they were stored in a tube containing 5mL of BHI (Brain Heart Infusion) liquid medium. Then, samples were transported to the Clinical Analysis Laboratory/Microbiology Sector where the microbiological analyzes were performed. Results: In total, 257 bacteria were observed, of which 5.11% were possible causes of hospital infection and 79% coagulase-negative Staphylococcus. Antibiograms of these were performed and different resistance profiles were found. The bathroom doorknob, a high-touch surface, presented the greatest variety of species among the evaluated surfaces. Conclusion: Surfaces and equipment of the evaluated clinic present possible bacteria that cause hospital infection with different profiles of antimicrobial resistance, contributing to possible cross infections.(AU)


Subject(s)
Bacteria , Bacterial Infections , Cross Infection , Equipment Contamination , Patient Safety , Drug Resistance, Microbial
6.
Rev. bras. enferm ; 74(3): e20200759, 2021. graf
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1288354

ABSTRACT

ABSTRACT Objectives: to evaluate the microbial load and adherence of Escherichia coli in different areas of the surgical instrument surface exposed to experimental contamination over time. Methods: experimental study in which fragments of crile forceps (serrated, rod and rack) were contaminated by immersion in Tryptic Soy Broth, containing 106 CFU/mL of E. coli, for 1, 2, 4, 6, 8, 12 and 24 hours. Microbial load and bacterial adherence were evaluated using microbiological culture and scanning electron microscopy, respectively. Results: there was an increase in the microbial load on the surgical instrument, proportional to the contamination interval, ranging from 102 after 1 hour to 105 CFU/cm2 in 24 hours. The presence of exopolysaccharide was detected after two hours of contamination. Conclusions: microbial load and adhesion of E. coli increased over time, reaching 105 CFU/cm2 after 24 hours of contamination, starting biofilm formation after two hours.


RESUMEN Objetivos: evaluar la carga microbiana y adherencia de Escherichia coli en diferentes áreas de la superficie de instrumento quirúrgico expuesto a la contaminación experimental a lo largo del tiempo. Métodos: estudio experimental en que fragmentos de tenacillas quirúrgicas (sierra, asta y cremallera), contaminados por inmersión en Tryptic Soy Broth, conteniendo 106 UFC/mL de E. coli, por 1, 2, 4, 6, 8, 12 y 24 horas. La carga microbiana y la adherencia bacteriana evaluadas con uso de cultivo y microscopia electrónica de barredura, respectivamente Resultados: verificó aumento de la carga microbiana en el instrumento quirúrgico, proporcional al intervalo de contaminación, variando de 102 tras 1 hora a 105 UFC/cm2 en 24 horas. La presencia de polisacárido detectada tras 2 horas de contaminación. Conclusiones: carga microbiana y adherencia de E. coli aumentaron a lo largo del tiempo, atingiendo 105 UFC/cm2 tras 24 horas de contaminación, iniciándose formación de biopelícula tras 2 horas.


RESUMO Objetivos: avaliar a carga microbiana e a aderência de Escherichia coli em diferentes áreas da superfície de instrumento cirúrgico exposto à contaminação experimental ao longo do tempo. Métodos: estudo experimental em que fragmentos de pinças crile (serrilha, haste e cremalheira) foram contaminados por imersão em Tryptic Soy Broth, contendo 106 UFC/mL de E. coli, por 1, 2, 4, 6, 8, 12 e 24 horas. A carga microbiana e a aderência bacteriana foram avaliadas com uso de cultura microbiológica e microscopia eletrônica de varredura, respectivamente. Resultados: verificou-se aumento da carga microbiana no instrumento cirúrgico, proporcional ao intervalo de contaminação, variando de 102 após 1 hora a 105 UFC/cm2 em 24 horas. A presença de exapolissacarídeo foi detectada após 2 horas de contaminação. Conclusões: carga microbiana e aderência de E. coli aumentaram ao longo do tempo, atingindo 105 UFC/cm2 após 24 horas de contaminação, iniciandose formação de biofilme após 2 horas.

7.
Cogit. Enferm. (Online) ; 26: e74774, 2021. tab
Article in Portuguese | LILACS-Express | LILACS, BDENF | ID: biblio-1345900

ABSTRACT

RESUMO Objetivo: descrever o perfil de resistência a antimicrobianos de microrganismos presentes em superfícies inanimadas. Método: estudo descritivo, realizado entre fevereiro e junho de 2018. Coletou-se 40 amostras microbiológicas de superfícies da Clínica Médica e Unidade de Terapia Intensiva Adulto em um hospital de Mato Grosso, Brasil. A identificação e sensibilidade microbiana foram realizadas através do VITEK-2. A análise dos resultados de resistência foi avaliada conforme as diretrizes do Clinical Laboratory Standards Institute. Resultados: foram isolados 32 microrganismos das 22 amostras contaminadas, dentre eles 14 (43,8%) Staphylococcus coagulase negativa, sete (21,9%) Acinetobacter baumanni complex, três (9,4%) Enterobacter aerogenes. Dentre os Staphylococcus coagulase negativa, 11 (78,6%) apresentaram multirresistência a antimicrobianos e três (42,9%) dos isolados de Acinetobacter baumanni complex foram extremamente resistentes. Conclusão: evidenciou-se a necessidade de educação com ênfase na desinfecção correta e frequente de superfícies e na higienização das mãos após tocar o paciente e as superfícies próximas a ele.


RESUMEN Objetivo: describir el perfil de resistencia de microrganismos presentes en superficies inanimadas a agentes antimicrobianos. Método: estudio descriptivo realizado entre febrero y junio de 2018. Se recolectaron 40 muestras microbiológicas de superficies de la Clínica Médica y de la Unidad de Cuidados Intensivos para Adultos de un hospital de Mato Grosso, Brasil. Los procesos de identificación y sensibilidad microbiana se realizaron a través del dispositivo VITEK 2. El análisis de los resultados de resistencia se evaluó conforme a las directrices del Clinical Laboratory Standards Institute. Resultados: se aislaron 32 microrganismos de las 22 muestras contaminadas; entre ellos, hubo 14 (43,8%) Staphylococcus coagulasa negativa, siete (21,9%) Acinetobacter baumanni complex y tres (9,4%) Enterobacter aerogenes. Entre los Staphylococcus coagulasa negativa, 11 (78,6%) presentaron multi-resistencia a agentes antimicrobianos y tres (42,9%) de los aislados bacterianos de Acinetobacter baumanni complex fueron extremamente resistentes. Conclusión: se hizo evidente la necesidad de instrucción con énfasis en la correcta y frecuente desinfección de superficies y en el lavado de manos después de entrar en contacto con el paciente y con las superficies próximas al paciente.


ABSTRACT Objective: to describe the antimicrobial resistance profile of microorganisms present on inanimate surfaces. Method: a descriptive study, conducted between February and June 2018. Forty microbiological samples were collected from surfaces of the Medical Clinic and Intensive Care Unit for Adults in a hospital located in Mato Grosso, Brazil. Microbial identification and sensitivity were performed by means of VITEK 2. The analysis of the resistance results was assessed according to the Clinical Laboratory Standards Institute guidelines. Results: a total of 32 microorganisms were isolated from the 22 contaminated samples, the following among them: 14 (43.8%) Coagulase-Negative Staphylococcus, seven (21.9%) Acinetobacter baumanni complex, and three (9.4%) Enterobacter aerogenes. Of the Coagulase-Negative Staphylococcus, 11 (78.6%) presented multi-drug resistance to antimicrobial agents, and three (42.9%) of the Acinetobacter baumanni complex isolates were extremely resistant. Conclusion: this study evidenced the need for education with emphasis on proper and frequent disinfection of surfaces and on hand hygiene after touching patients and surfaces close to them.

8.
Rev Rene (Online) ; 22: e61222, 2021. graf
Article in Portuguese | BDENF, LILACS | ID: biblio-1250667

ABSTRACT

RESUMO Objetivo analisar a prática da desinfecção dos oxímetros de dedo realizada pelos profissionais de Enfermagem. Métodos estudo quantitativo, descritivo e transversal com nove profissionais em unidade clínica hospitalar. Coletaram-se 18 amostras com swab, uma interna e uma externa de cada equipamento, isolando-se 51 colônias bacterianas para a testagem de suscetibilidade aos antimicrobianos. Resultados os profissionais não recebiam capacitação para a desinfecção do aparelho. Oito transportavam os oxímetros nos jalecos e um, na bandeja. Raramente desinfetavam o interior do aparelho por receio do álcool etílico 70% danificar o sensor. Em 17 amostras, cresceram diferentes gêneros bacterianos. Foram multirresistentes aos antimicrobianos 17,7%. Conclusão observou-se que os profissionais de Enfermagem não desinfetam corretamente os oxímetros de dedo. Recomendam-se o uso de álcool isopropílico 70% para desinfetar os sensores, por este não danificar o equipamento, e o uso de álcool etílico 70% na higienização dos dedos dos pacientes antes e após os testes.


ABSTRACT Objective to analyze the practice of disinfection of finger oximeters by nursing professionals. Methods a quantitative, descriptive, and cross-sectional study with nine professionals in a hospital clinical unit. Eighteen swab samples were collected, internally and externally from each equipment, isolating 51 bacterial colonies for antimicrobial susceptibility testing. Results the professionals were not trained to disinfect the equipment. Eight carried the oximeters in their lab coats, and one carried them on a tray. They rarely disinfected the inside of the device fearing the 70% ethyl alcohol would damage the sensor. In 17 samples, different bacterial genera grew. 17.7% were multidrug-resistant to antimicrobials. Conclusion it was observed that Nursing professionals don't disinfect finger oximeters correctly. The use of 70% isopropyl alcohol is recommended to disinfect the sensors, since it doesn't damage the equipment, and 70% ethyl alcohol to sanitize the patients' fingers before and after the tests.


Subject(s)
Disinfection , Equipment Contamination , Nursing , Drug Resistance, Bacterial , Nurse Practitioners
9.
Rev. Soc. Bras. Med. Trop ; 53: e20200244, 2020. tab, graf
Article in English | SES-SP, ColecionaSUS, LILACS | ID: biblio-1136857

ABSTRACT

Abstract INTRODUCTION: Contaminated hospital environments contribute to the transmission of microorganisms associated with healthcare. Contaminated surfaces handled by patients or healthcare professionals are a source of microorganism transmission by hand. Methicillin-resistant Staphylococcus bacteria are among the main agents responsible for increasing healthcare-associated infections in Brazil and worldwide. METHODS: The objective of this study was to screen and characterize methicillin-resistant Staphylococcus spp. on surfaces near patients in an intensive care unit. Microbiological samples, collected from ten beds in an intensive care unit with five sampling sites, were inoculated into a methicillin-resistant Staphylococcus aureus chromogenic medium. MALDI-TOF and PCR analyses were used to identify the bacteria. Antimicrobial susceptibility was determined using the disk diffusion test. The presence of the mecA gene was investigated using PCR. RESULTS: We observed that 44 out of the 50 sampling sites presented grown isolates in the methicillin-resistant Staphylococcus aureus medium. The incidence of isolated microorganisms on the right side rail, left side rail, tables, infusion pump keypad, and cardiac monitor were 18.8 %, 36.7 %, 10.9 %, 2.4 %, and 31 %, respectively. The 42 isolates included in this study were identified as coagulase-negative Staphylococcus. All of these microorganisms were multidrug-resistant and mecA gene-positive. CONCLUSIONS: This study identified the presence of methicillin-resistant coagulase-negative Staphylococcus on the beds of an intensive care unit, providing evidence for the necessity of assertive actions to decrease the risk of healthcare-associated infections at the site.


Subject(s)
Humans , Staphylococcal Infections , Methicillin-Resistant Staphylococcus aureus/genetics , Staphylococcus/genetics , Bacterial Proteins , Brazil , Microbial Sensitivity Tests , Methicillin Resistance , Hospitals , Intensive Care Units , Anti-Bacterial Agents/pharmacology
10.
Rev. bras. enferm ; 73(1): e20180623, 2020. tab
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1057753

ABSTRACT

ABSTRACT Objective: To discuss the methods employed to evaluate the effectiveness of clinical surface cleaning and disinfection (C&D). Method: This is a theoretical reflection based on scientific studies and the experience of the authors. Knowledge and current gaps, the need for further studies, and practical application of the methods were approached. Results: There are four main methods used to evaluate the effectiveness of clinical surface C&D: visual inspection, fluorescent markers, microbiological cultures, and adenosine triphosphate (ATP) bioluminescence. The first two are used to evaluate the process and to predict adherence to protocols by the staff, and the last two are employed to evaluate the results, therefore being the most relevant to assess the risk of infection. Final considerations: The ideal method was not found, because all of them showed limitations. There is a need for strategies to optimize the precision of these methods.


RESUMEN Objetivo: Discutir los métodos utilizados para evaluar la eficiencia de la limpieza y desinfección (L&D) de superficies clínicas. Método: Reflexión teórica fundamentada en estudios científicos y en la experiencia de los autores. Fueron abordados el conocimiento y las carencias presentes, la necesidad de investigaciones futuras y la práctica en la aplicación de los métodos. Resultados: Los métodos más habitualmente aplicados para evaluar la eficiencia de la L&D de superficies clínicas son cuatro: inspección visual, marcadores fluorescentes, cultivos microbiológicos y test de adenosina trifosfato por bioluminiscencia. Los dos primeros son utilizados para evaluar el proceso. Prevén la adhesión a los protocolos por parte del equipo. Los dos últimos son aplicados para evaluar los resultados, por lo cual son más relevantes para descubrir riesgos de infección. Consideraciones finales: No se encontró el método ideal, dado que todos presentan limitaciones. Se necesitan estrategias que optimicen la precisión de estos métodos.


RESUMO Objetivo: Discutir os métodos empregados para avaliar a eficiência da limpeza e desinfecção (L&D) de superfícies clínicas. Método: Trata-se de uma reflexão teórica fundamentada em estudos científicos e experiência dos autores. Foram abordados o conhecimento e as lacunas atuais, a necessidade de futuras investigações e a prática na utilização dos métodos. Resultados: São quatro os principais métodos utilizados para avaliar a eficiência da L&D de superfícies clínicas: inspeção visual, marcadores fluorescentes, culturas microbiológicas e teste de adenosina trifosfato por bioluminescência. Os dois primeiros são utilizados para avaliar o processo e preveem a adesão aos protocolos pela equipe, enquanto os dois últimos são empregados para avaliar os resultados, portanto, mais relevantes na avaliação do risco de infecção. Considerações finais: Não foi encontrado um método ideal, pois todos apresentaram limitações. São necessárias estratégias que potencializem a precisão desses métodos.

11.
Rev. peru. med. exp. salud publica ; 36(4): 676-680, oct.-dic. 2019. tab
Article in Spanish | LILACS | ID: biblio-1058777

ABSTRACT

RESUMEN Con el objetivo de identificar la presencia de microorganismos en los teléfonos móviles del personal de la unidad de cuidados intensivos (UCI) de un hospital en España se realizó un estudio transversal descriptivo entre los profesionales sanitarios y no sanitarios que tuvieran teléfonos móviles durante su jornada laboral. La recogida de muestras se llevó a cabo mediante hisopo y siembra en placa de cultivo con análisis e identificación de los microorganismos. Se analizaron 111 teléfonos móviles, de los cuales 56 estaban contaminados siendo 41,5% y 41,1% para los que pertenecían a las enfermeras y los médicos respectivamente y 60,6% para la encontrada en los auxiliares de enfermería, destaca el crecimiento de Pseudomonas aeruginosa (12,5%), Staphylococus aureus meticilin-resistente (10,9%), y Stenotrophomonas maltophila (4,7%). En conclusión, los teléfonos móviles presentaron presencia de microorganismos de relevancia clínica. La presencia de estas bacterias y hongos deben alertarnos sobre la posibilidad de que sirvan de reservorio para la transmisión al paciente crítico.


ABSTRACT In order to identify the presence of microorganisms in mobile phones of the staff from the intensive care unit (ICU) at a hospital in Spain, a cross-sectional descriptive study was carried out among healthcare and non-healthcare professionals who had mobile phones during their working day. Samples were collected by swabbing and sowing on a culture plate with analysis and identification of microorganisms. One hundred eleven (111) mobile phones were analyzed, of which 56 were contaminated: 41.5% and 41.1% of those belonging to nurses and physicians, respectively, and 60.6% found in nursing assistants. The growth of Pseudomonas aeruginosa (12.5%), methicillin-resistant Staphylococcus aureus (10.9%), and Stenotrophomonas maltophila (4.7%) stand out. In conclusion, mobile phones presented the presence of clinically relevant microorganisms.


Subject(s)
Humans , Personnel, Hospital , Bacteria/isolation & purification , Cell Phone , Fungi/isolation & purification , Spain , Equipment Contamination , Cross-Sectional Studies , Intensive Care Units
12.
Int. j. odontostomatol. (Print) ; 13(3): 357-362, set. 2019. tab
Article in English | LILACS | ID: biblio-1012436

ABSTRACT

ABSTRACT: The contamination of the dental units' waterlines is a reality, which can develop individual and collective disorders. The aim of this study was to evaluate the prevalence and resistance profile of bacteria on the internal surfaces of waterlines in a dental clinic from a Dentistry school of a Brazilian university. The design was an exploratory, descriptive study with quantitative and qualitative approach. Samples (n=4) were collected for analysis at different points: the portion closest to the water reservoir of the chair, and the portion closest to the triple syringe. After collection the samples were cultured in BHI medium in an oven for 24-48 h at 37 °C. For the quantitative analysis 1 ml of each sample was used for serial dilution up to the dilution value seven. The colonies were counted after pour plate and the results expressed in UFC/cm2. The qualitative analysis was initiated with the cultivation of Agar Blood, EMB-Levine and Cetrimide Agar for 24 h, and the identification of bacteria was performed by microscopic analyses. The resistance profile was verified by classical antibiogram. The internal surfaces of unit waterlines units exhibited a mean of 2.44 x 109 CFU / cm2. Bacillus subtilis and Pseudomonas aeruginosa were identified. The resistance profile of Pseudomonas aeruginosa indicated sensitivity to all tested antibiotics. A large number of microorganisms was quantified from biofilm accumulated in the dental units' waterlines. However, they were not resistant to classic antibiogram. Better management and application of decontamination protocols for waterlines need to be applied since opportunistic infections may be associated with Pseudomonas aeruginosa.


RESUMEN: La contaminación de líneas de agua en las unidades dentarias es una realidad, generando enfermedades individuales y colectivas. El objetivo de este estudio fue evaluar la prevalencia y resistencia de las bacterias en las zonas internas de las líneas de agua de la Facultad de Odontología de una universidad brasileña. El diseño del estudio fue exploratorio, descriptivo con enfoques cuantitativos y cualitativos. Las muestras para análisis (n=4) fueron selecionadas de distintos lugares: el punto más cercano al sistema de agua del sillón odontológico y el punto más cercano a la jeringa tríplice. Las muestras obtenidas fueron cultivadas en un médio BHI por 24-48 h, en un horno a 37 ºC. Para el análisis cuantitativo, se utilizó 1 ml de cada muestra para dilución hasta el valor siete. Las colonias fueran contadas y los resultados fueron expresados en UFC/cm2. El análisis cualitativo fue iniciado con el cultivo de Agar Sangre, EBM-Levine y Agar Cetrimide por 24 h y la identificación de la bacteria fue realizada por análisis microscópicos. El perfil de resistencia fue verificado por el antibiograma clásico. Las zonas internas de las unidades de líneas de agua mostraron un promédio de 2,44 x 109 UFC/cm2. Bacillus subtilis y Pseudomonas aeruginosa fueron encontrados. El perfil de resistencia de Pseudomonas aeruginosa indicó sensibilidad a todos los antibióticos testados. Un gran número de microorganismos fue cuantificado desde la biopelícula acumulada en las líneas de agua de unidades dentales. Sin embargo, no resistieron al antibiograma clásico. Se requiere una mejor gestión y aplicación de protocolos de decontaminación en las líneas de agua debido a que las infecciones oportunistas puedan estar asociadas a Pseudomonas aeruginosa.


Subject(s)
Humans , Water/adverse effects , Biofilms , Infection Control, Dental/methods , Water Microbiology , Brazil , Colony Count, Microbial , Equipment Contamination/prevention & control , Prospective Studies , Dental Equipment/microbiology , Mycobacterium/growth & development
13.
Rev. Pesqui. (Univ. Fed. Estado Rio J., Online) ; 11(4): 951-956, jul.-set. 2019. tab
Article in English, Portuguese | BDENF, LILACS | ID: biblio-1005775

ABSTRACT

Objetivo: Descrever as condições de limpeza de superfícies inanimadas comuns ao toque dos pacientes e da equipe de saúde após limpeza terminal em unidade de terapia intensiva. Método: Estudo prospectivo, experimental, desenvolvido entre novembro e dezembro de 2016. Foram avaliadas 44 superfícies próximas ao paciente, por meio da inspeção visual e método microbiológico. Resultados: Visualmente, todas as superfícies encontravam-se secas e limpas. Pelo método de coloração de Gram, verificaram-se microrganismos em 81,8% dos leitos. Foram encontrados microrganismos em 40,9% de superfícies, principalmente nas grades de camas. Em bombas infusoras não foram observados microrganismos. Em 38,8% das amostras encontrou-se Bacilos Gram negativos. Conclusão: Há necessidade de mudanças no comportamento da equipe de saúde, assim como a revisão dos protocolos de desinfecção como formas de reduzir às Infecções Relacionadas à Assistência à Saúde


Objetive: Describe the cleaning conditions of inanimate surfaces common to the patients' and healthcare team's touch after terminal cleaning in an intensive care unit. Methods: A prospective, experimental study was carried out between November and December 2016. Fourty-four areas close to the patient were evaluated by visual inspection and microbiological method. Results: Visually, all surfaces were dry and clean. Gram staining method showed microorganisms in 81.8% of the beds. Microrganisms were found in 40.9% of surfaces, mainly in beds. No microorganisms were observed in infusion pumps. In 38.8% of the samples Gram-negative bacilli were found. Conclusion: There is a need for changes in the health team's behavior, as well as the revision of disinfection protocols as a way to reduce Health Care-related Infections


Objetivo: Describir las condiciones de limpieza de superficies inanimadas comunes al tacto de los pacientes y equipo de salud después de la limpieza terminal en una unidad de terapia intensiva. Método: Estudio prospectivo, experimental, desarrollado entre noviembre y diciembre de 2016. Se evaluaron 44 superficies cercanas al paciente, por medio de la inspección visual y método microbiológico. Resultados: De forma visual, todas las superficies se encontraban secas y limpias. Por el método de tinción de Gram, se verificaron microorganismos en el 81,8% de los lechos. Se encontraron microorganismos en 40,9% de superficies, principalmente en las rejillas de camas. En bombas infusoras no se observaron microorganismos. En el 38,8% de las muestras se encontró Bacilos Gram negativos. Conclusión: Hay necesidad de cambios en el comportamiento del equipo de salud, así como la revisión de los protocolos de desinfección como formas de reducir las Infecciones relacionadas con la Atención de la Salud


Subject(s)
Cross Infection , Equipment Contamination , Housekeeping, Hospital , Disinfection , Intensive Care Units/standards
14.
Rev. latinoam. enferm. (Online) ; 27: e3125, 2019. graf
Article in Portuguese | LILACS, BDENF | ID: biblio-1004251

ABSTRACT

Objetivos durante a punção venosa periférica, recomenda-se o uso de um garrote acima do local da punção para potencializar a distensão venosa. Dadas as suas características e o uso em ambientes clínicos, os garrotes podem representar uma fonte de disseminação de micro-organismos. Entretanto, os resultados de estudos científicos nessa área estão dispersos na literatura. Esta revisão de escopo tem como objetivo mapear as evidências disponíveis a respeito das práticas dos profissionais de saúde no que concerne ao uso do garrote durante a punção venosa periférica e à contaminação microbiológica associada. Método revisão de escopo de acordo com a metodologia do Instituto Joanna Briggs. Dois revisores independentes analisaram a relevância dos estudos, extraíram e sintetizaram dados. Resultados quinze estudos foram incluídos na revisão. Em geral, os garrotes foram reutilizados sem processos de descontaminação recorrentes. Verificou-se que os profissionais compartilham esses dispositivos entre si e os usaram continuamente por períodos entre duas semanas e sete anos e meio. Conclusão as práticas de enfermagem relacionadas ao uso do garrote durante a punção venosa periférica não são uniformes. A reutilização de garrotes pode colocar em risco a segurança do paciente se o reprocessamento (limpeza e desinfecção/esterilização) não for adequado, dado o tipo de material do garrote e a microbiota encontrada. Novos estudos são necessários para avaliar o impacto de vários tipos de práticas de reprocessamento na descontaminação de garrotes e na segurança do paciente.


Objectives during peripheral venipuncture, health professionals are recommended to use a tourniquet above the puncture site in order to potentiate venous distension. Given its characteristics and use in clinical settings, tourniquets may represent a source of microorganism dissemination. However, the results of scientific studies in this area are scattered in the literature. This scoping review aims to map the available evidence on health professionals' practices related with tourniquet use during peripheral venipuncture and associated microbiological contamination. Methods scoping review following the Joanna Briggs Institute methodology. Two independent reviewers analyzed the relevance of the studies, extracted and synthesized data. Results fifteen studies were included in the review. Overall, tourniquets were reused without being subject to recurring decontamination processes. It has been found that practitioners share these devices among themselves and use them successively for periods between two weeks and seven and half years. Conclusion nursing practices related to tourniquet use during peripheral venipuncture are not standard. Reuse of tourniquets may jeopardize the patient's safety if reprocessing (cleaning and disinfection/sterilization) is not adequate, given the type of tourniquet material and microbiota found. New studies are needed to assess the impact of various types of reprocessing practices on tourniquet decontamination and patient safety.


Objetivos durante la punción venosa periférica, se recomienda el uso de un garrote arriba del sitio de la punción para potenciar la distensión venosa. Dadas sus características y uso en ambientes clínicos, los garrotes pueden representar una fuente de diseminación de microorganismos. Sin embargo, los resultados de estudios científicos en esta área están dispersos en la literatura. Esta revisión de alcance tiene como objetivo mapear las evidencias disponibles acerca de las prácticas de los profesionales de salud en lo que concierne al uso del garrote durante la punción venosa periférica y la contaminación microbiológica asociada. Método revisión de alcance de acuerdo con la metodología del Instituto Joanna Briggs. Dos revisores independientes analizaron la relevancia de los estudios, extrajeron y sintetizaron datos. Resultados quince estudios se incluyeron en la revisión. En general, los garrotes fueron reutilizados sin procesos de descontaminación recurrentes. Se verificó que los profesionales comparten estos dispositivos entre sí y los utilizaron continuamente por períodos entre dos semanas y siete años y medio. Conclusión las prácticas de enfermería relacionadas al uso del garrote durante la punción venosa periférica no son uniformes. La reutilización de garrotes puede poner en riesgo la seguridad del paciente si el reprocesamiento (limpieza y desinfección/esterilización) no es adecuado, dado el tipo de material del garrote y la microbiota encontrada. Nuevos estudios son necesarios para evaluar el impacto de varios tipos de prácticas de reprocesamiento en la descontaminación de garrotes y en la seguridad del paciente.


Subject(s)
Humans , Professional Practice , Catheterization/methods , Central Venous Pressure/physiology , Disinfection/instrumentation , Equipment Contamination/prevention & control , Portugal , Health Personnel , Phlebotomy/methods
15.
J. bras. pneumol ; 45(3): e20170351, 2019. tab
Article in English | LILACS | ID: biblio-1012549

ABSTRACT

ABSTRACT Objective: Home nebulizers are routinely used in the treatment of patients with cystic fibrosis (CF). This study aims to evaluate the contamination of nebulizers used for CF patients, that are chronically colonized by Pseudomonas aeruginosa, and the association of nebulizer contamination with cleaning, decontamination and drying practices. Methods: A cross-sectional, observational, multicenter study was conducted in seven CF reference centers in Brazil to obtain data from medical records, structured interviews with patients/caregivers were performed, and nebulizer's parts (interface and cup) were collected for microbiological culture. Results: overall, 77 CF patients were included. The frequency of nebulizer contamination was 71.6%. Candida spp. (52.9%), Stenotrophomonas maltophilia (11.9%), non-mucoid P. aeruginosa (4.8%), Staphylococcus aureus (4.8%) and Burkholderia cepacia complex (2.4%) were the most common isolated pathogens. The frequency of nebulizers' hygiene was 97.4%, and 70.3% of patients reported cleaning, disinfection and drying the nebulizers. The use of tap water in cleaning method and outdoor drying of the parts significantly increased (9.10 times) the chance of nebulizers' contamination. Conclusion: Despite the high frequency hygiene of the nebulizers reported, the cleaning and disinfection methods used were often inadequate. A significant proportion of nebulizers was contaminated with potentially pathogenic microorganisms for CF patients. These findings support the need to include patients/caregivers in educational programs and / or new strategies for delivering inhaled antibiotics.


RESUMO Objetivo: Nebulizadores caseiros são usados rotineiramente no tratamento de pacientes com fibrose cística (FC). Este estudo objetiva avaliar a contaminação de nebulizadores utilizados por pacientes de FC que estão cronicamente colonizados por Pseudomonas aeruginosa e a associação da contaminação do nebulizador com a higienização, esterilização e método de secagem. Métodos: Um estudo transversal, observacional, multicêntrico foi conduzido em sete centros de referência de FC no Brasil para obter dados de registros médicos; foram feitas entrevistas estruturadas com os pacientes/cuidadores e partes de nebulizadores (máscara e copo) foram coletados para cultura microbiológica. Resultados: No geral, 77 pacientes com FC foram incluídos. A frequência da contaminação do nebulizador foi de 71,6%. Candida spp. (52,9%), Stenotrophomonas maltophilia (11,9%), P. aeruginosa não mucoide (4,8%), Staphylococcus aureus (4,8%) e complexo Burkholderia cepacia (2.4%) foram os patógenos isolados mais comuns. A frequência de higienização dos nebulizadores foi de 97,4%, e 70,3% dos pacientes relata higienização, esterilização e secagem dos aparelhos. A lavagem com água da torneira e secagem das partes no tempo, em espaço aberto, aumentou significativamente (9 a 10 vezes) a chance de contaminação dos nebulizadores. Conclusões: Apesar dos relatos de frequente higienização dos nebulizadores, os métodos de limpeza e esterilização usados eram inadequados. Uma proporção significativa de nebulizadores foi contaminada com microrganismos potencialmente patogênicos para pacientes com FC. Estes resultados apoiam a necessidade de inclusão dos pacientes/cuidadores em programas educacionais e/ou novas estratégias para fornecimento de antibióticos inalatórios.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Young Adult , Pseudomonas aeruginosa/isolation & purification , Nebulizers and Vaporizers/microbiology , Equipment Contamination/statistics & numerical data , Cystic Fibrosis/therapy , Reference Values , Brazil , Colony Count, Microbial , Logistic Models , Decontamination/methods , Decontamination/statistics & numerical data , Disinfection/methods , Disinfection/statistics & numerical data , Equipment Contamination/prevention & control , Cross-Sectional Studies
16.
Rev. méd. Minas Gerais ; 29: [1-6], 2019. graf
Article in Portuguese | LILACS | ID: biblio-1008922

ABSTRACT

Introdução: As infecções relacionadas à assistência a saúde (IRAS) tem crescido de forma progressiva favorecendo a disseminação dos mesmos. Dentre as superfícies inanimadas presentes em um ambiente hospitalar, a torneira é uma das mais contaminadas, pela possível formação de biofilme. Objetivos: Avaliar a presença de bactérias patogênicas no interior, exterior e maçanetas de corpo de torneiras, bem como seu perfil de suscetibilidade aos antimicrobianos. Métodos: Foram coletadas amostras de 11 torneiras de diversos setores do hospital, com swab estéril em meio Stuart. Estas foram inoculadas em caldo Brain Heart Infusion (BHI), incubadas por 24 horas em estufa de aerobiose a 35ºC. Foram repicadas em Ágar Manitol Salgado, Ágar MacConkey e Ágar Sangue e incubadas por 24-48 horas em aerobiose a 35º ± 2ºC. Após o período de incubação foram realizadas as provas bioquímicas e o teste de suscetibilidade aos antimicrobianos. Resultados: Das 33 amostras analisadas, houve crescimento de bactérias patogênicas em 12 (36,4%) amostras. Dentre os microorganismos isolados nas torneiras, encontraram-se 6 cepas de Pseudomonas sp (50%), 3 de Klebsiella pneumoniae(25%), 1 cepa de Enterobacter cloacae (8,33%), 1 cepa de Escherichia coli (8,33%), 1 cepa de Staphyloccocus aureus(8,33%) entre superfícies internas, externas e maçanetas. Conclusões: Foram isoladas cepas de Escherichia coli, Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas sp e Staphylococcus aureus do interior, exterior e maçanetas de corpo de torneiras do Hospital de Ensino avaliado neste estudo. Além disso, observou-se multirresistência às drogas das cepas isoladas, e presença de mecanismos de resistência como ESBL e MRSA. (au)


Introduction: Infection related to health care (IRAS) have been increasing progressively, as the number of micro-organisms resistant to antimicrobials has increased, favoring their spread. Among the inanimate surfaces present in a hospital environment, the tap is one of the most contaminated, due to possible biofilm formation. Objectives: To evaluate the presence of pathogenic bacteria in the interior, exterior and faucet body handles, as well as its profile of antimicrobial susceptibility. Methods: Samples were collected 11 taps from different sectors of the hospital, with sterile swab in Stuart medium. These were inoculated in BHI broth, incubated for 24 hours in greenhouse aerobically, at 35º C. They were picked Agar Manitol Salt, Agar, MacConkey Agar and Blood Agar and incubated for 24-48 hours aerobically to 35º ± 2ºC. After the incubation period, the biochemical tests and antimicrobial susceptibility test were performed. Results: Of the 33 samples analyzed, there was growth of pathogenic bacteria in 12 (36.4%) samples. Six isolates of Pseudomonas sp (50%), 3 of Klebsiella pneumoniae (25%), 1 Enterobacter cloacae strain (8.33%), 1 strain of Escherichia coli (8.33%), 1 strain of Staphyloccocus aureus (8.33%) between internal, external surfaces and door handles. Conclusions: Strains of Escherichia coli, Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas sp and Staphylococcus aureus from the interior, exterior and faucet body handles of the Teaching Hospital evaluated in this study were isolated. In addition, we observed multidrug resistance of strains isolated, and presence of resistance mechanisms such as ESBL and MRSA. (AU)


Subject(s)
Drug Resistance, Microbial , Cross Infection , Equipment Contamination , Delivery of Health Care , Delivery of Health Care/statistics & numerical data
17.
Rev. epidemiol. controle infecç ; 8(4): 409-414, out.-dez. 2018. ilus
Article in Portuguese | LILACS | ID: biblio-1015001

ABSTRACT

Justificativa e Objetivos: Os ambientes hospitalares podem albergar microrganismos patogênicos e oportunistas, sendo o processo de limpeza e desinfecção importante para o controle das Infecções relacionadas à Assistência à Saúde (IRAS). Assim, o objetivo deste trabalho foi avaliar a eficácia do álcool etílico e do quaternário de amônio no processo de desinfecção de equipamentos médicos hospitalares previamente contaminados com Staphylococcus aureus (S. aureus). Métodos: descontaminação de 10 equipamentos médicos hospitalares contaminados com uma suspensão de S. aureus ATCC 25923. A descontaminação ocorreu com álcool etílico nas concentrações de 46,2%, 70% e 99% e com o quaternário de amônio de 1ª e de 5ª geração. Após a descontaminação, foram colhidas amostras da superfície dos equipamentos para cultura bacteriana. Resultados: foi verificado crescimento bacteriano em 80% dos equipamentos descontaminados com álcool 46,2% e 99%. Não houve crescimento bacteriano na superfície dos equipamentos descontaminados com álcool 70% e quaternários de amônio. Conclusão: os processos de desinfecção com álcool 70% e quaternário de amônio de 1ª e 5ª geração foram eficazes no controle do S. aureus, comprovando a ação efetiva destes produtos na desinfecção dos equipamentos médicos hospitalares.(AU)


Background and Objectives: Hospital environments may harbor pathogenic and opportunistic microorganisms, and the cleaning and disinfection process is important for the control of Health Care Related Infections (IRAS). Thus, the objective of this work to evaluate compare the efficacy of ethyl alcohol and quaternary ammonium in the disinfection of hospital medical equipment against Staphylococcus aureus (S. aureus). Methods: decontamination of 10 hospital medical equipment contaminated with a suspension of S. aureus ATCC 25923. The decontamination occurred with ethyl alcohol at concentrations of 46.2%, 70% and 99% and with the quaternary ammonium of 1st generation and 5th generation. After the decontamination, samples were harvested from the surface of the equipment for bacterial culture. Results: bacterial growth was verified in 80% of the equipment decontaminated with alcohol 46.2% and 99%. There was no bacterial growth on the surface of equipment decontaminated with alcohol 70% and quaternary ammonium. Conclusions: the disinfection processes with alcohol 70% and quaternary ammonium 1st and 5th generation were effective in the control of S. aureus, proving the effectiveness of these products in the disinfection of hospital medical equipment.(AU)


Justificación y objetivos: Los ambientes hospitalarios pueden albergar microorganismos patógenos y oportunistas, siendo el proceso de limpieza y desinfección importante para el control de las Infecciones relacionadas a la Asistencia a la Salud (IRAS). Así, el objetivo de este trabajo evaluar comparar la eficacia del alcohol etílico y del cuaternario de amonio en el proceso de desinfección de equipos médicos hospitalarios previamente contaminados con Staphylococcus aureus (S. aureus). Métodos: la descontaminación de 10 equipos médicos hospitalarios contaminados con una suspensión de S. aureus ATCC 25923. La descontaminación ocurrió con alcohol etílico en las concentraciones de 46,2%, 70% y 99% y con el cuaternario de amonio de 1ª y de 5ª generación. Después de la descontaminación, se tomaron muestras de la superficie de los equipos para cultivo bacteriano. Resultados: se verificó crecimiento bacteriano en el 80% de los equipos descontaminados con alcohol 46,2% y 99%. No hubo crecimiento bacteriano en la superficie de los equipos descontaminados con alcohol 70% y cuaternarios de amonio. Conclusión: los procesos de desinfección con alcohol 70% y cuaternario de amonio de 1ª y 5ª generación fueron eficaces en el control del S. aureus, comprobando la acción efectiva de estos productos en la desinfección de los equipos médicos hospitalarios.(AU)


Subject(s)
Humans , Staphylococcus aureus , Disinfection , Ethanol , Infections
18.
Rev. Eugenio Espejo ; 12(1): 44-52, Jun.- 2018.
Article in Spanish | LILACS | ID: biblio-980678

ABSTRACT

El presente estudio comprende el análisis y la eliminación de los microorganismos presentes en los sistemas de irrigación de las unidades dentales de la Universidad Nacional de Chimbo-razo, el mismo tiene como finalidad la reducción de contaminación microbiana. Se procedió a tomar muestras del agua del sistema de irrigación que recorre por la jeringa triple de diez unidades dentales escogidas al azar, la recolección se realizó en un solo día, en envases estéri-les y fueron trasladados de manera inmediata hacia los laboratorios de la facultad de Ciencias Químicas de la UNACH- L.S.A. El análisis de la carga microbiana se realizó a través de un procedimiento in vitro en el laboratorio con cultivos sembrados en agar nutritivo de marca comercial Difco, se interpretaron los resultados, se verificó si estos valores están dentro de los parámetros internacionales para el uso y consumo humano, confirmando que existen valores mayores a las 200 UFC/ml. Finalmente, se procedió a la desinfección del agua, la que se realizó con hipoclorito de sodio al 5% y con digluconato de clorhexidina al 2%, cinco unidades detales para cada desinfectante respectivamente, se repitió el procedimiento de recolección de muestras así como también de análisis microbiológico post desinfección, se verificaron los resultados y se comparó la efectividad entre los desinfectantes empleados en la investigación, obtenido ausencia de UFC/ml para cada sustancia utilizada, dando el mante-nimiento al agua de los sistemas de irrigación.


A comparative observational study was carried out in the Dental Clinic of Universidad Nacional de Chimborazo (UNACH), during the academic period October 2015 - February 2016. The object of study was given by the existing microbial load in the irrigation system of 10 dental units; as well as the effect of 5% sodium hypochlorite and chlorhexidine diglucona-te on it. The samples were collected in two moments: after disinfection and after procedure performed. The intakes were made at the distal end of the irrigation systems of the triple syringe of the dental units, eliminating the amount of water that runs through the whole pipe and then obtaining the sample without interrupting the water flow in a sterile bottle. A total of 10 samples were collected, one from each dental unit, immediately closing the bottle and transferring them to the UNACH laboratory for processing. Before carrying out the disinfec-tion process, the laboratory results showed microbial contamination figures in the irrigation systems of the dental units above the acceptable values of CFU (Colony Forming Units). The use of 5% sodium hypochlorite and 2% chlorhexidine digluconate showed the effectiveness of these substances as antimicrobials in the disinfection of irrigation systems of dental units with similar levels of effectiveness in this regard.


Subject(s)
Humans , Sodium Hypochlorite , Disinfection , Dental Disinfectants , Therapeutic Irrigation , Equipment Contamination , Dental Clinics , Anti-Infective Agents
19.
Korean Journal of Medicine ; : 41-49, 2018.
Article in Korean | WPRIM | ID: wpr-741113

ABSTRACT

BACKGROUND/AIMS: Due to a lack of scientific evidence and unstandardized protocols, the correct use of personal protective equipment (PPE) is not always easy for healthcare personnel (HCP). This study aimed to generate experimental evidence to reduce contaminations during PPE doffing. METHODS: With institutional review board approval, 4 standardized HCP were recruited to examine selected PPE protocols based on consultations with 10 invited Korean infection control leaders. Using fluorescent powder and ultraviolet light, each PPE protocol was evaluated for contaminations by comparing methods or steps. Pictures of contaminated areas and videos of HCP practice were evaluated for case analysis by linking all collected data using assigned study experiment codes. RESULTS: A total of 38 simulation experiments were conducted during December 14–20, 2016. No significant difference was found among minor variations in PPE protocols. Rather, after an intensive, 1-minute patient care simulation (e.g., physical assessment), severe powder contaminations on the front and under the sleeves of coveralls were found. Even after the outer-glove surface was wiped clean, partial contaminations still remained, especially between fingers and on fingertips. Moreover, after cleaning glove surface contaminations using wipes, each doffing step caused different contaminations. Among different types of N95 respirators, the foldable N95 type was the most stable during doffing processes, with less possibility of contamination. CONCLUSIONS: Based on this study's findings with visual evidence of contaminations during PPE doffing processes, some meaningful recommendations were feasible, such as the use of disposable long-sleeve aprons over coveralls. Further study is necessary to evaluate these recommendations.


Subject(s)
Humans , Delivery of Health Care , Equipment Contamination , Ethics Committees, Research , Fingers , Health Personnel , Infection Control , Patient Care , Personal Protective Equipment , Referral and Consultation , Ultraviolet Rays , Ventilators, Mechanical
20.
Rev. bras. enferm ; 70(6): 1176-1183, Nov.-Dec. 2017. tab, graf
Article in English | LILACS, BDENF | ID: biblio-898311

ABSTRACT

ABSTRACT Objective: to assess the correlation among the ATP-bioluminescence assay, visual inspection and microbiological culture in monitoring the efficiency of cleaning and disinfection (C&D) of high-touch clinical surfaces (HTCS) in a walk-in emergency care unit. Method: a prospective and comparative study was carried out from March to June 2015, in which five HTCS were sampled before and after C&D by means of the three methods. The HTCS were considered dirty when dust, waste, humidity and stains were detected in visual inspection; when ≥2.5 colony forming units per cm2 were found in culture; when ≥5 relative light units per cm2 were found at the ATP-bioluminescence assay. Results: 720 analyses were performed, 240 per method. The overall rates of clean surfaces per visual inspection, culture and ATP-bioluminescence assay were 8.3%, 20.8% and 44.2% before C&D, and 92.5%, 50% and 84.2% after C&D, respectively (p<0.001). There were only occasional statistically significant relationships between methods. Conclusion: the methods did not present a good correlation, neither quantitative nor qualitatively.


RESUMEN Objetivo: evaluar correlación del test ATP-bioluminiscencia con inspección visual y cultivo microbiológico en monitoreo de eficiencia de limpieza y desinfección (L&D) de superficies clínicas altamente tocadas (SCAT) en unidad de pronta atención. Métodos: estudio comparativo, prospectivo, realizado de marzo a junio de 2015, cuando cinco SCAT fueron muestreadas antes y después de L&D de rutina por los tres métodos. Las SCAT fueron consideradas sucias cuando presentaban: en inspección visual: polvo, deyecciones, humedad y manchas; en cultivo: ≥205 unidades formadoras de colonias por cm2, y en ATP-bioluminiscencia: ≥5 Unidades Relativas de Luz por cm2. Resultados: fueron realizadas 720 evaluaciones, 240 por método. La tasa global de superficies limpias por inspección visual, cultivo y ATP-bioluminiscencia fue, respectivamente, 8,3%, 20,8% y 44,2% antes de la L&D y de 92,5%, 50% y 84,2% después (p<0,001). Existieron sólo asociaciones puntuales estadísticamente significativas entre los métodos. Conclusión: los métodos no presentan buena correlación cuantitativa, ni cualitativa.


RESUMO Objetivo: avaliar a correlação do teste de ATP-bioluminescência com inspeção visual e cultura microbiológica na monitorização da eficiência da limpeza e desinfecção (L&D) de superfícies clínicas altamente tocadas (SCAT) em unidade de pronto atendimento. Métodos: estudo comparativo, prospectivo, conduzido de março a junho de 2015, de forma que cinco SCAT foram amostradas antes e depois da L&D de rotina pelos três métodos. As SCAT foram consideradas sujas quando apresentaram: na inspeção visual, poeira, dejetos, umidade e manchas; na cultura, ≥2,5 unidades formadoras de colônias por cm2 e; no ATP-bioluminescência, ≥5 Unidades Relativas de Luz por cm2. Resultados: foram realizadas 720 avaliações, sendo 240 por método. A taxa global de superfícies limpas por inspeção visual, cultura e ATP-bioluminescência foi, respectivamente, de 8,3%, 20,8% e 44,2% antes da L&D e de 92,5%, 50% e 84,2% após (p<0,001). Houve apenas associações pontuais estatisticamente significativas entre os métodos. Conclusão: os métodos nem apresentaram boa correlação quantitativa, nem, qualitativa.


Subject(s)
Humans , Disinfection/methods , Disinfection/standards , Brazil , Prospective Studies , Infection Control/methods , Infection Control/standards , Luminescent Measurements/methods
SELECTION OF CITATIONS
SEARCH DETAIL